2. až 4. 11. 2017 - Konference Léčba v psychiatrii III – navštivte nás na našem stánku, kde budeme mít k dispozici ECT přístroje Mecta spECTrum a VOG systémy Medicton

Clarion Congress Hotel, České Budějovice (Pražská třída 2306/14, 370 04 České Budějovice) - http://akce.psychiatrie.cz/

 


9. 11. 2017 – Přednáška MUDr. Jakuba Albrechta (VFN v Praze): Neuromodulační metody léčby duševních poruch ČVUT v Praze, Fakulta elektrotechnická, posluchárna 209 (Technická 2, 166 27 Praha 6)

 


14. 11. 2017 – Přednáška profesora Harolda A. Sackeima, Ph.D. (Columbia University): Electroconvulsive therapy in the Age of Brain Stimulation: Past, Present, and Future ČVUT v Praze, Fakulta elektrotechnická, posluchárna 135 (Technická 2, 166 27 Praha 6)

 


15. 11. 2017 – Přednáška profesora Harolda A. Sackeima, Ph.D. (Columbia University): Electroconvulsive therapy in the Age of Brain Stimulation: Past, Present, and Future Knihovna Psychiatrické kliniky 1. LF UK a VFN Praha (Ke Karlovu 11, Praha 2) – pozvánka zde


SpECTrum is an electroconvulsive medical device that has an LCD touch screen with rich menu, where all stimulus parameters are displayed. In addition, for type Q, we can modify the four parameter sets of Pulse Width (starting from 0,3ms), Frequency, Duration and Current. The devices are available with choice for maximum energy of 100J or 200J.

 

Each placement of stimulus electrodes is accompanied by static impedance monitoring and calculated dynamic impedances. Each 5000 model spECTrum purchase includes the choice of two monitoring channels: EEG 1 and EEG 2, or EEG 1 and an ECG channel. However up to four additional monitoring channels may be added to an EEG/ECG base model, wich makes a total of  6 channels (4 EEG, 1 ECG and 1 OMS-optical motion sensor).

 

The 2-channel Chart Recorder can register 2 EEG (or from selection of EEG, ECG, OMS)

The 5000 devices include EEG Data Analysis, which provides real-time Seizure Adequacy estimates (developed in collaboration with Duke University, protected by US patents). It gives to the clinician the estimated probability, that an induced seizure has been supraliminal and sets the multiplier factor exceeding the seizure threshold.

 




spECTrum 5000M / 5000Q




spECTrum 5000M

 

  • Single stimulus knob to varie Frequency and Duration simultaneosly, to control Energy and Charge,
  • LCD touch screen with menu, including all stimulation data and static impedance monitoring
  • Two monitoring channels (2 * EEG or ECG + EEG) on display
  • The model can be extended to 3 up to 6 channels (ECG, EEG and 4 * OMS)
  • Two-channel thermal Chart Recorder

 


spECTrum 5000Q

 

  • Four stimulus knobs (Pulse Width, Frequency, Duration and Current), to control Energy and Charge,
  • LCD touch screen with menu, including all stimulation data and static impedance monitoring
  • Two monitoring channels (2 * EEG or ECG + EEG) on display
  • The model can be extended to 3 up to 6 channels (ECG, EEG and 4 * OMS)
  • Two-channel thermal Chart Recorder 




spECTrum 4000M / 4000MQ



spECTrum 4000M

 

  • Single stimulus knob to varie Frequency and Duration simultaneosly, to control Energy and Charge,
  • LCD touch screen with menu, including all stimulation data and static impedance monitoring
  •  

 

spECTrum 4000Q

 

  • Four stimulus knobs (Pulse Width, Frequency, Duration and Current), to control Energy and Charge,
  • LCD touch screen with menu, including all stimulation data and static impedance monitoring